Testing your building automation system once a year is a thing of the past. BACtive is a Niagara module that puts active fault detection at your fingertips, with BACtive Diagnostics, BACtive Monitoring, and BACtive Alarming working together.

Available nowBACtive Diagnostics, BACtive Monitoring, and BACtive Alarming all ship in one custom Niagara module.
Tests your system on demand and delivers a clear diagnostic report showing which units passed, which need attention, and why, so you know where to send a technician before anyone climbs a ladder.
Watches all of your equipment around the clock, so offline devices, stale readings, and rooms running hot or cold get caught before the complaints come in.
Alerts your team the moment an equipment fault that matters happens, with delays that filter out nuisance alarms. Every alarm lands in its own dedicated alarm console.
Every test run ends in a clear BACtive Diagnostic Report: an executive summary, a priority overview, and a recommended service plan grouped into repair packages, with every piece of equipment listed.



See the average temperature on every floor and the exact zones running hot or cold, so the right equipment gets attention before the complaints come in.
Every BACtive Alarming alarm arrives with a clear title, the live readings behind it, how long it has been going on, and a short list of things to check in the field.
| Timestamp | Source | Alarm Title / Alarm Details | Priority | Ack |
|---|---|---|---|---|
| 11/20 2:14 PM | BACtiveAlarming/ProofFail | AHU-1 supply fan proof failureSupply fan is commanded on but status is off (12 minutes) | High | Unacked |
| 11/20 1:58 PM | BACtiveAlarming/DatOffSp | AHU-2 discharge air temp off setpointCooling is at 100% but discharge air reads 63.8°F with a 55.0°F setpoint (45 minutes) | High | Unacked |
| 11/20 12:40 PM | BACtiveAlarming/Offline | VAV-2-09 offlineIs offline (not communicating) (2 hours) | Medium | Unacked |
| 11/20 11:05 AM | BACtiveAlarming/StaticOffSp | AHU-1 duct static off setpointStatic reads 0.62 inWC with a 1.2 inWC setpoint (25 minutes) | Medium | Acked |
| 11/20 8:31 AM | BACtiveAlarming/Frozen | AHU-2 frozen sensorDischargeAirTemp is frozen at 55.2°F (6 hours) | Medium | Acked |
| 11/17 10:12 AM | BACtiveAlarming/In8 | VAV-3-12 point at In8DamperPosition is at In8 (operator override) (3 days & 4 hours) | Low | Acked |
AHU-1 supply fan proof failure Supply fan is commanded on but status is off (12 minutes) Things to check - Belt, motor, and disconnect - Current switch or airflow proof switch and its setting - VFD fault, or the HOA switch left in Hand or Off - Safeties (smoke detector, freezestat, high static, door switch) - Start relay / starter output from the host Alarms provided by BAC Advanced Solutions
BACtive is one custom Niagara module, built by BAC Advanced Solutions.
Problems get caught and sent to the right person before the complaints come in.
See your building clearly from one screen, with reports and alarms in one place.